Re: Is logoff feature necessary May 03 2006 01:30PM
Andrew van der Stock (vanderaj greebo net)
I can answer this for a particular product suite: WebSeal and
WebSphere using LTPA cookies, due to some research I can't directly
share.

If a WebSeal junction has a 15 minute idle out, and WebSphere a 20
minute idle out, users cannot re-connect to the WebSphere application
after 15 minutes,...